Function
Use this command to list the sub-flow OLPC parameters of a typical traffic RAB.
OLPC: Outer Loop Power Control. The OLPC algorithm adjusts the target values for the inner loop power control based on the communication quality, such as the Block Error Rate (BLER), Bit Error Rate (BER), and Frame Error Rate (FER) parameters. Thus, the minimum power can always meet the communication requirements.
Note
None.
Parameter
Parameter ID | Parameter Name | Parameter Description |
---|---|---|
QueryType | Query type | Meaning: Select query typical RAB condition type. GUI Value Range: QUERY_BY_RABINDEX, QUERY_BY_PROPERTY Actual Value Range: QUERY_BY_RABINDEX, QUERY_BY_PROPERTY Unit: None Default Value: QUERY_BY_RABINDEX Recommended Value: QUERY_BY_RABINDEX |
RabIndex | Service parameter index | Meaning: Index number uniquely identifying the configuration of the typical service parameters. GUI Value Range: 0~99 Actual Value Range: 0~99 Unit: None Default Value: None Recommended Value: None |
CNDomainId | CN domain ID | Meaning: This parameter specifies whether the service is a CS service or PS service. - CS_DOMAIN: Circuit Switched domain service - PS_DOMAIN: Packet Switched domain service GUI Value Range: CS_DOMAIN, PS_DOMAIN Actual Value Range: CS_DOMAIN, PS_DOMAIN Unit: None Default Value: None Recommended Value: None |
TrafficClass | Traffic class | Meaning: Traffic class. There are four traffic classes: conversational, streaming, interactive, and background. GUI Value Range: CONVERSATIONAL, STREAMING, INTERACTIVE, BACKGROUND Actual Value Range: CONVERSATIONAL, STREAMING, INTERACTIVE, BACKGROUND Unit: None Default Value: None Recommended Value: None |
MaxBitRate | Max rate[bit/s] | Meaning: Maximum bit rate of the typical traffic. GUI Value Range: 0~256000000 Actual Value Range: 0~256000000 Unit: bit/s Default Value: None Recommended Value: None |
TrchType | Transport channel type | Meaning: This parameter specifies the type of uplink transport channel for the typical RAB. GUI Value Range: TRCH_DCH, TRCH_EDCH_2MS, TRCH_EDCH_10MS Actual Value Range: TRCH_DCH, TRCH_EDCH_2MS, TRCH_EDCH_10MS Unit: None Default Value: None Recommended Value: None |
DelayClass | Delay Class | Meaning: Delay class number. Each delay class number indicates a specified delay time range of Iub transmission. GUI Value Range: 1~5 Actual Value Range: 1~5 Unit: None Default Value: None Recommended Value: None |
LstFormat | Result list format | Meaning: This parameter indicates the result is listed horizontally or vertically. GUI Value Range: HORIZONTAL, VERTICAL Actual Value Range: HORIZONTAL, VERTICAL Unit: None Default Value: VERTICAL Recommended Value: VERTICAL |
Example
To list the OLPC related configurations of the typical traffic RAB that has the following configuration: - CN domain ID: PS_DOMAIN - Traffic class: CONVERSATIONAL - Max rate[bit/s]: 64000 - Transport channel type: TRCH_DCH - Delay Class: 1 Execute the following command: LST UTYPRABOLPC: QueryType=QUERY_BY_PROPERTY, CNDomainId=PS_DOMAIN, TrafficClass=CONVERSATIONAL, MaxBitRate=64000, TrchType=TRCH_DCH, DelayClass=1; After the above operation, the result is shown as follows: %%LST UTYPRABOLPC: QueryType=QUERY_BY_PROPERTY, CNDomainId=PS_DOMAIN, TrafficClass=CONVERSATIONAL, MaxBitRate=64000, TrchType=TRCH_DCH, DelayClass=1;%% RETCODE = 0 Execution succeeded. List Typical RAB OLPC Parameters -------------------------------- Service parameter index = 15 Service subflow index = 0 Transport channel type = TRCH_DCH Delay Class = 1 Target value of service DCH_BLER = -20 Maximum Number of E-DCH PDU retransfer[times] =Edch Little Target Number of E-DCH PDU retransfer[times] = Maximum E-DCH SIR decrease step[0.001dB] = Edch Target Large Number of E-DCH PDU retransfer[times] = Traffic Class = CONVERSATIONAL (Number of results = 1) 1 reports in total --- END
Output Description
Refer to the parameter description of ADD UTYPRABOLPC.